Calculators.
General
Unit Conversion
Periodic Table
Piping
Darcy Weisbach
Heating piping
Water Hammer
Electrical
Voltage Drop
kVAR calculator
Motor protection
Motor sizing
|
|
Piping friction loss Calculator.
This Little program will calculate for
you the friction loss through a pipe using the popular Darcy-Weisbach
equation :
hf = f * ( L / D) * (V2 / 2 * g).
In order to calculate the minor losses
(fittings) you must add the corresponding Km values from the table below
, and enter them in the Km textbox of applet.
The value of friction factor f
is calculated using the colebrook equation , and can be checked using
the Moody diagram.
| Fitting |
Km |
| Globe valve, fully
open |
10.00 |
| Angle valve, fully
open |
2.00 |
| Gate valve, fully
open |
0.15 |
| Gate valve, 1/2
closed |
2.10 |
| Swing check valve
, flow |
2.00 |
| Elbow 90o
- flanged |
0.30 |
| Elbow 90o
- threaded |
1.50 |
| Long radius 90°,
flanged |
0.20 |
| Long radius 90°,
threaded |
0.70 |
| Elbow 45°,
threaded |
0.40 |
| Tee , Line flow,
flanged |
0.20 |
| Tee , Line flow,
threaded |
0.90 |
| Tee , Branch flow,
flanged |
1.00 |
| Tee , Branch flow,
threaded |
2.00 |
| Piping Entry &
Exit |
1.00 |
If you experience problems using the
calculator or need additional information, post your questions on the message
board.
Before
using the calculators
please read the Copyright and Disclaimer Notice.
|
|